By International Code Council

ISBN-10: 1580017347

ISBN-13: 9781580017343

ISBN-10: 1580017355

ISBN-13: 9781580017350

The 2009 overseas gasoline fuel Code units forth specifications that deal with the layout and install of gasoline fuel structures and gas-fired home equipment, in accordance with the most up-tp-date details and expertise to be had. the necessities are performance-driven, making this an efficient instrument and beneficial addition to any Code library.

Show description

Read or Download 2009 International Fuel Gas Code: Looseleaf Version PDF

Similar design & construction books

Construction Project Management

As expanding calls for and better expectancies are put on venture managers a necessity has arisen for an cutting edge ebook to permit managers to tackle the ever-changing demanding situations focused on overseeing entire works and working with the conflicting wishes of the numerous humans focused on a building undertaking.

Building regulations in brief

Specifications of the construction laws; licensed files; management of the development laws; making plans Permission and native specialists; Environmental keep an eye on; safeguard; caliber

Facility Management: Erfolg in der Immobilienbewirtschaftung

Der Management-Leitfaden zur Einführung und Umsetzung von Facility administration erscheint bereits in der 6. Auflage. Die Neubearbeitung der Themen reicht von der nachhaltigen Gebäudebewirtschaftung über die Problematik bei der Einführung einer elektronischen Gebäudeakte, bis hin zur Produktionssteigerung mit Hilfe eines CAFM-Gebäudeinformationssystems und trägt damit dem heutigen Stand der Technik Rechnung.

Social network analysis in construction

The target of the e-book is to teach how social community research (SNA) is used to monitor, visual display unit and examine the complicated relationships in significant development undertaking coalitions. content material: advent -- intent for a community method of the research of venture administration platforms -- twenty first century reform and emergent structures in building -- the development undertaking as a method of interdependent governance networks -- Social community research as a study approach -- community case reviews -- analyzing community diagrams -- Mathematical research of community info -- handling networks -- precis, conclusions and ultimate concepts.

Extra resources for 2009 International Fuel Gas Code: Looseleaf Version

Sample text

For other than steel pipe, exposed piping shall be identified by a yellow label marked "Gas" in black letters. The marking shall be spaced at intervals not exceeding 5 feet (1524 mm). The marking shall not be required on pipe located in the same room as the appliance served. 6 Interconnections. Where two or more meters are installed on the same premises but supply separate consumers, the piping systems shall not be interconnected on the outlet side of the meters. 7 Piping meter identification. Piping from multiple meter installations shall be marked with an approved permanent identification by the installer so that the piping system supplied by each meter is readily identifiable.

1 Appliances installed in rooms that are large in comparison with the size of the appliance. Air-conditioning appliances installed in rooms that are large in comparison with the size of the appliance shall be installed with clearances in accordance with the manufacturer's instructions. 2 Appliances installed in rooms that are not large in comparison with the size of the appliance. Air-conditioning appliances installed in rooms that are not large in comparison with the size of the appliance, such as alcoves and closets, shall be listed for such installations and installed in accordance with the manufacturer's instructions.

For the purpose of this section, rooms or spaces that are not part of the living space of a dwelling unit and that communicate directly with a private garage through openings shall be considered to be part of the private garage. Exception: Elevation of the ignition source is not required for appliances that are listed as flammable vapor ignition resistant. 8. Combustion air intake openings located on the exterior of a building shall have the lowest side of such openings located not less than 12 inches (305 mm) vertically from the adjoining finished ground level.